TITLE: HANDRAIL
DEFICIENCY 1: HANDRAIL MISSING
DEFICIENCY CRITERIA: Handrail is missing (i.e., evidence of prior installation, but now not present or is incomplete).
HEALTH AND SAFETY DETERMINATION: Moderate
CORRECTION TIMEFRAME:                         30 days
HCV Pass / Fail                                                Fail
HCV – CORRECTION TIMEFRAME:             30 days
DEFICIENCY 2: HANDRAIL IS NOT SECURE
DEFICIENCY CRITERIA: There is movement in the anchors of the handrail.
HEALTH AND SAFETY DETERMINATION: Moderate
CORRECTION TIMEFRAME:                         30 days
HCV Pass / Fail                                                Fail
HCV – CORRECTION TIMEFRAME:             30 days
DEFICIENCY 3: HANDRAIL IS NOT FUNCTIONALLY ADEQUATE
DEFICIENCY CRITERIA: Handrail is not functionally adequate (i.e., it cannot reasonably be grasped by hand to provide stability or support when ascending or descending stairways).
OR
Handrail is not continuous for the full length of each stair flight.
OR
Handrail is not between 28 inches and 42 inches in height.
HEALTH AND SAFETY DETERMINATION: Moderate
CORRECTION TIMEFRAME:                         30 days
HCV Pass / Fail                                                Fail
HCV – CORRECTION TIMEFRAME:             30 days
DEFICIENCY 4: HANDRAIL IS NOT INSTALLED WHERE REQUIRED.
DEFICIENCY CRITERIA: 4 or more stair risers are present, and a handrail is not installed.
OR
A ramp has a rise greater than 6 inches or a horizontal projection greater than 72 inches and a handrail is not installed on both sides.
HEALTH AND SAFETY DETERMINATION: Low
CORRECTION TIMEFRAME:                         60 days
HCV Pass / Fail                                               Pass
HCV – CORRECTION TIMEFRAME:             N/A
MORE INFORMATION: Handrail Standard
Back to content