TITLE: FOUNDATION-Unit
DEFICIENCY 1: FOUNDATION
IS CRACKED
DEFICIENCY
CRITERIA: Crack is present with a width of ¼ inch
or greater and a length of 12 inches or greater.
HEALTH
AND SAFETY
DETERMINATION:MODERATE
CORRECTION TIMEFRAME: 30
days
HCV
Pass / Fail
Fail
HCV – CORRECTION TIMEFRAME: 30
days
DEFICIENCY 2 – OUTSIDE: FOUNDATION
VENT COVER IS MISSING OR DAMAGED.
DEFICIENCY
3: FOUNDATION HAS EXPOSED REBAR OR
FOUNDATION IS SPALLING, FLAKING, OR CHIPPING
DEFICIENCY
CRITERIA: The structure has any exposed rebar.
OR
Foundation is spalling, flaking, or
chipping and the affected area is 12x12 inches or greater and goes into the foundation
at a depth of ¾ inch or greater.
HEALTH AND SAFETY
DETERMINATION:MODERATE
CORRECTION TIMEFRAME: 30 days
HCV Pass / Fail
Fail
HCV – CORRECTION TIMEFRAME:
30
days
DEFICIENCY 4: FOUNDATION
INFILTRATED BY WATER
DEFICIENCY
CRITERIA: Evidence of water infiltration through
foundation.
HEALTH AND SAFETY
DETERMINATION:MODERATE
CORRECTION
TIMEFRAME: 30 days
HCV Pass / Fail
Fail
HCV – CORRECTION TIMEFRAME:
30
days
DEFICIENCY
5 : FOUNDATION SUPPORT POST, COLUMN, BEAM,
OR GIRDER is DAMAGED
DEFICIENCY
CRITERIA: Any support post, column, or girder
area is damaged (i.e., visibly defective; impacts functionality).
HEALTH AND SAFETY
DETERMINATION:MODERATE
CORRECTION TIMEFRAME: 30 days
HCV Pass / Fail
Fail
HCV – CORRECTION TIMEFRAME:
30
days
MORE INFORMATION: Foundation Standard